Vertical Stack Water Source Heat Pumps

High efficiencies for utility rebates and incentive programs

vertical stackDaikin is pleased to announce our new and improved Vertical Stack Heat Pump Model VHC (Chassis) and VHF (Cabinet) in unit sizes 009 to 036 with non-ozone-depleting R-410A refrigerant and efficiencies that exceed ASHRAE 90.1 by up to 50%. Using customer feedback, we have developed a vertical stack product that includes many of the options that markets demand, while allowing for optional future growth.

Vertical stack units are designed for use in multiple floor apartments, office buildings, hotels, nursing homes and other similar applications. They require a minimum amount of floor space and are designed for multiple discharge arrangements.

  • Efficiencies up to 24.1 EER - 50% higher than the current ASHRAE 90.1 minimum, and most models exceed minimum thresholds for most utility rebate and incentive programs
  • Optional dactory installed hydronic heat coil to help reduce energy consumption by using hot loop water temperatures to condition a space without energizing mechanical heating
  • Geothermal models available
  • Optional factory installed MERV 8 filters for improved indoor air quality
  • Optional factory installed 2-way motorized valves (NO or NC) – ideal for variable pumping applications – when there isn't a call for unit operation, the valve closes, reducing the flow requirements through the condenser water loop. This option reduces installation and operating costs
  • Optional auto-flow regulators to ensure proper water flow rate through the unit
  • Optional front-mounted disconnect switch allows user to turn off power to the unit for service/maintenance
  • Optional motorized outdoor air damper module allows compatibility with outdoor air applications
  • Optional compressor sound blankets for unit sizes 021 to 036 – helps to attenuate compressor noise
  • Optional ECM motors - 4 field-selectable CFM settings and 28 programmed CFM values, helping to reduce sound levels and savings on operating energy Multiple riser and cabinet options available to accommodate your specific application
  • eQuest® Ready! Click here to download product input files for use with eQUEST® energy modeling software.
  • Sound data available!

Specifications

Vertical Stack Performance Data

Unit Size
Air Flow
Water Flow
Water Loop (*PSC) Water Loop (*ECM)
Cooling Heating Cooling Heating
cfm L/S GPM L/S Btu/hr EER Btu/hr COP Btu/hr EER Btu/hr COP
009 450 142 2.5 0.16 9300 13.8 11200 4.6 9700 15.1 11400 5.0
012 450 189 3.0 0.19 11700 12.8 14500 4.5 12000 14.0 14400 4.7
015 500 236 3.5 0.22 14400 13.5 18300 4.8 14300 15.0 18200 5.1
018 500 283 4.2 0.26 16600 13.0 22500 4.9 16900 13.6 22400 5.0
021 700 330 5.4 0.34 20300 13.9 24400 4.8 20500 14.5 24100 4.8
024 800 378 6.0 0.38 23000 14.3 28000 4.9 23400 14.8 27800 5.0
030 1000 472 7.3 0.46 29400 14.7 34700 5.0 29400 15.2 34300 5.1
036 1200 566 9.0 0.57 35600 14.1 41600 4.7 35300 14.4 42000 4.7
Data shown based on 208/230-60-1 voltage