Enfinity™ Horizontal Ceiling Mounted
Water Source Heat Pumps

Lowest Possible Profile for Space-Saving Applications

enfinityDaikin Enfinity™ water source heat pumps incorporate the best of our past and the best of what's new. Using feedback from building owners, consulting engineers, contractors and service engineers, we designed Enfinity products to give you maximum flexibility to design, install, operate and maintain the ideal water source heat pump system for your building project.

  • Non-CFC, R-410A refrigerant
  • Standard or geothermal application flexibility
  • Easy, low cost design and installation
  • High efficiency reduces energy consumption/operating costs and can contribute to earning LEED® points and rebates
  • Superior indoor air quality and quiet operation
  • Easy, low cost maintenance and service
  • MicroTech® III unit controls with Open Choices™ feature allows standalone or network operation using LonWorks® or BACnet® communication options
  • Performance rated with ISO Standard 13256-1
  • eQuest® Ready! Click here to download product input files for use with eQUEST® energy modeling software.

Specifications

Enfinity Small Vertical Dimensions
Unit Size Dimensions
L W H
007 34 20 11.5
009 34 20 11.5
012 40 20 11.5
015 42 20 19
019 42 20 19
024 42 20 19
030 46 21 20
036 46 21 20
042 52 28 23
048 52 28 23
060 52 28 23
Small Enfinity Horizontal Performance Data (w/PSC Fan Motors)

Unit Size
Air Flow
Water Flow
Water Loop (Boiler Tower) Ground Loop
Cooling Heating Cooling Heating
cfm L/S GPM L/S Btu/hr EER Btu/hr COP Btu/hr EER Btu/hr COP
007 300 142 2.1 0.14 8000 11.8 10,700 4.2 8900 14.4 7100 3.1
009 300 142 2.3 0.14 8800 12.9 11,800 4.6 9200 14.8 7400 3.3
012 400 189 3.0 0.19 12,900 12.7 15,800 4.3 13,900 15.0 10,400 3.1
015 630 297 3.8 0.24 15,700 16.0 18,100 5.2 16,900 18.7 11,500 3.7
019 630 297 5.3 0.33 21,000 14.9 23,600 4.8 22,600 17.3 14,700 3.6
024 800 378 6.2 0.39 24,700 14.4 28,400 4.7 26,300 16.6 18,000 3.6
030 1000 472 7.6 0.48 30,400 15.3 36,200 5.0 31,500 17.7 23,100 3.6
036 1200 566 9.0 0.57 35,800 15.2 42,500 4.9 37,800 17.7 28,400 3.6
042 1400 661 10.7 0.68 43,000 15.0 50,700 5.0 44,500 17.1 33,900 3.7
048 1600 755 12.3 0.78 48,400 14.1 57,100 4.7 50,200 16.1 38,400 3.7
060 2000 944 15.2 0.96 59,500 14.6 69,400 4.9 61,500 16.8 47,500 3.7
Small Enfinity Horizontal Dimensions (w/ECM Fan Motors)

Unit Size

Dimensions
L W H
015 42 20 19
019 42 20 19
024 42 20 19
030 46 21 20
036 46 21 20
042 52 28 23
048 52 28 23
060 52 28 23
070 52 28 23
Small Enfinity Horizontal Performance Data (w/ECM Fan Motors)

Unit Size
Air Flow
Water Flow
Water Loop (Boiler Tower) Ground Loop
Cooling Heating Cooling Heating
cfm L/S GPM L/S Btu/hr EER Btu/hr COP Btu/hr EER Btu/hr COP
015 500 297 3.8 0.24 16,000 17.6 18,100 5.6 17,200 20.8 11,500 4.0
019 630 297 5.3 0.33 20,900 15.7 23,700 5.1 22,600 18.4 14,800 3.8
024 800 378 6.2 0.39 24,700 14.7 28,500 4.9 26,300 17.0 18,100 3.7
030 1000 472 7.6 0.48 30,500 15.9 36,100 5.3 31,600 18.4 23,000 3.8
036 1200 566 9.0 0.57 36,000 16.0 42,400 5.2 38,000 18.8 28,700 3.8
042 1400 661 10.7 0.68 43,000 15.5 51,600 5.2 44,100 17.9 34,600 3.8
048 1600 755 12.3 0.78 48,700 15.6 57,700 5.2 50,600 18.2 39,300 3.9
060 2000 944 15.2 0.96 59,700 15.5 69,300 5.2 61,700 17.9 48,000 3.9
070 2330 944 18.0 1.14 71,300 12.7 88,100 4.2 73,800 14.3 59,300 3.3
Large Enfinity Horizontal Dimensions

Unit Size

Dimensions
L W H
072 78 44 29
096 78 44 29
120 78 44 29
Large Enfinity Horizontal Performance Data

Unit Size
Air Flow
Water Flow
Water Loop (Boiler Tower) Ground Loop
Cooling Heating Cooling Heating
cfm L/S GPM L/S Btu/hr EER Btu/hr COP Btu/hr EER Btu/hr COP
072 2400 1133 20.1 1.27 78,100 13.4 82,700 4.4 77,700 16.3 58,700 3.7
096 3000 1416 23.6 1.49 94,900 14.8 94,300 4.3 97,300 16.8 66,100 3.3
120 4000 1888 30.1 1.9 121,000 12.6 135,000 4.3 125,000 14.1 81,500 3.2