Skyline™ Commercial Outdoor Air Handlers

Designed and engineered for flexibility and performance

skylineQuality construction makes Skyline units both airtight and weathertight. Our patented, gasketed frame channel, double-wall, injected-foam panels and crossbroken top panels are just a few features that help keep conditioned air inside the cabinet and Mother Nature outside. The result is lower operating costs and superior indoor air quality (IAQ) over years of reliable service.

Over 70 years of research, testing and innovation by Daikin have combined to bring you flexible air handling systems with outstanding performance and cost efficiency. With Daikin, you can expect value — from easy design and specification, to efficient installation and operation and low cost maintenance for the life of your Skyline unit. With the ability to attain a maximum of Class 6 leakage up to +/-8'' of internal static per ASHRAE's 111 Standard, Skyline is a viable solution for any building requiring improved indoor air quality, as well high static pressure, low leak applications like healthcare, cleanroom and labs.

  • Low leakage construction with up to +/-8" of internal static pressure
  • Dual direct drive plenum fans, fan array, and energy recovery sections for greater operating efficiency
  • Modular platform, 2-inch Variable Dimensioning™, multiple component options, and unlimited configurations for increased flexibility
  • Extensive coil selections including cooling, heating, steam and evaporator coils with extended connections and gasketed seals
  • Advanced filtration with HEPA, PCO, and low pressure filters
  • Higher indoor air quality using ultra-violet lights, stainless steel drain pan, and anti-microbial liner options
  • Energy recovery selections including fixed plate heat exchanger and energy recovery wheel(s)
  • Easy maintenance via access and service vestibules, inward swinging doors, and inside door handles

Specifications

Data Unit Size
003 004 006 008 010 012
Airflow range, cfm 900–
2500
1200–
3100
1700–
4600
2200–
6000
2900–
7700
3600–
9700
cfm @ 500 ft/min through large face area coil 1550 1950 2850 3750 4800 6050
Height × width, inches 32 × 38 36 × 40 38 × 52 40 × 58 44 × 64 50 × 66
Cooling coil face area, sq ft
Extended/staggered large 3.9 4.8 6.6 8.5 10.7 13.5
Large 3.1 3.9 5.7 7.5 9.6 12.1
Extended/staggered medium 2.6 3.4 4.7 6.4 8.3 9.8
Medium 2.1 2.8 4.1 5.6 7.4 8.8
Small N/A 2.3 3.3 4.7 6.4 7.7
Fan section–depth, inches
Largest housed fan & motor avail. w/ top hor. dischg. 32 32 36 40 40 46
Largest inline fan and motor available N/A N/A N/A N/A N/A 44
Largest belt drive plenum fan & motor available N/A N/A N/A N/A 34 42
Largest direct drive plenum fan & motor available N/A N/A N/A 44 46 56
Largest twin fan and motor available N/A N/A N/A 50 54 56
Largest 1 × 3 fan array and motor available N/A N/A N/A N/A N/A N/A
Largest 2 × 2 fan array and motor available N/A N/A N/A N/A N/A N/A
Largest 2 × 3 fan array and motor available N/A N/A N/A N/A N/A N/A
Mixing box–depth, inches
Mixing box only 20 20 20 20 22 24
Mixing box with flat filter 24 24 24 24 26 28
Mixing box with angular filter 42 42 42 42 44 46
Economizer–depth, inches
  66 66 70 66 74 72
Blender–depth, inches
Largest Kees 18 20 24 26 28 34
Largest Blender Products IV 18 22 26 30 34 38
Side load filter sections–depth, inches
Flat 2" and 4" 12 12 12 12 12 12
2" angular 32 32 32 32 32 32
Cartridge (12" deep w/2" pre-filter) 22 22 22 22 22 22
Bag (36" w/2" pre-filter) 42 42 42 42 42 42
Front load filter sections–depth, inches
Cartridge (12" deep w/2" pre-filter) 16 16 16 16 16 16
Bag (36" w/2" pre-filter) 40 40 40 40 40 40
Face and bypass–depth, inches
Internal 12 12 12 12 12 12
External 18 18 18 20 22 24
Coil sections–depth, inches
Heating only (2-row water) 12 12 12 12 12 12
Cooling only (4-row water) 24 24 24 24 24 24
Cooling only (6-row water) 24 24 24 24 24 24
Cooling & reheat (12-row cooling & 1-row heating) 36 36 36 36 36 36
Access sections–depth, inches
16" deep 16 16 16 16 16 16
24" deep 24 24 24 24 24 24
30" deep 30 30 30 30 30 30
36" deep 36 36 36 36 36 36
42" deep 42 42 42 42 42 42
48" deep 48 48 48 48 48 48
54" deep 54 54 54 54 54 54
Diffuser–depth, inches
With housed fan 10 10 10 12 12 16
With inline fan N/A N/A N/A N/A N/A 18
Attenuator–depth, inches
Short 40 40 40 40 40 40
Medium 52 52 52 52 52 52
Long 64 64 64 64 64 64
Supply or return plenum–depth, inches
Top, bottom or end opening 14 16 16 18 20 22
* Based on typical industry sizes. Vision air handling units are available in 2 inch increments of height and width to fit the exact space requirements.
Front load filter sections include 24" upstream plenum section with tread plate for heavy duty floor liner.

 Physical Data - 014 through 035

Data Unit Size
014 017 021 025 030 035
Airflow range, cfm 4200–
11,200
5000–
13,500
6000–
16,000
7300–
19,400
8500–
22,500
10,000–
26,500
cfm @ 500 ft/min through large face area coil 7000 8400 10,050 12,150 14,150 16,700
Height × width, inches 50 × 74 52 × 80 58 × 82 66 × 86 66 × 98 72 × 102
Cooling coil face area, sq ft
Extended/staggered large 15.4 18.3 21.9 27.4 31.9 37.1
Large 14.0 16.8 20.1 24.3 28.3 33.4
Extended/staggered medium 11.2 13.7 17.2 21.3 24.8 29.7
Medium 10.2 12.6 15.8 18.2 21.2 24.1
Small 8.9 11.2 14.4 16.7 19.5 22.3
Fan section–depth, inches
Largest housed fan & motor avail. w/ top hor. dischg. 46 50 52 58 58 58
Largest inline fan and motor available 44 48 54 64 64 70
Largest belt drive plenum fan & motor available 42 48 52 56 58 62
Largest direct drive plenum fan & motor available 56 66 68 66 68 84
Largest twin fan and motor available 58 58 66 66 74 82
Largest 1 × 3 fan array and motor available N/A 40 40 40 40 46
Largest 2 × 2 fan array and motor available N/A N/A 40 40 40 46
Largest 2 × 3 fan array and motor available N/A N/A 40 40 40 46
Mixing box–depth, inches
Mixing box only 24 26 30 32 32 36
Mixing box with flat filter 28 30 34
Mixing box with angular filter 46 48 52
Economizer–depth, inches
  77 80 84 84 86 100
Blender–depth, inches
Largest Kees 36 38 42 46 48 58
Largest Blender Products IV 40 46 48 52 60 64
Side load filter sections–depth, inches
Flat 2" and 4" 12 12 12 12 12 12
2" angular 32 30 30 32 32 32
Cartridge (12" deep w/2" pre-filter) 22 22 22 22 22 22
Bag (36" w/2" pre-filter) 42 42 42 42 42 42
Front load filter sections–depth, inches
Cartridge (12" deep w/2" pre-filter) 16 16 16 16 16 16
Bag (36" w/2" pre-filter) 40 40 40 40 40 40
Face and bypass–depth, inches
Internal 12 12 12 12 12 12
External 24 26 30 32 32 34
Coil sections–depth, inches
Heating only (2-row water) 12 12 16 12 12 12
Cooling only (4-row water) 24 24 24 36 36 36
Cooling only (6-row water) 24 24 24 42 42 42
Cooling & reheat (12-row cooling & 1-row heating) 36 36 36 42 42 42
Access sections–depth, inches
16" deep 16 16 16 16 16 16
24" deep 24 24 24 24 24 24
30" deep 30 30 30 30 30 30
36" deep 36 36 36 36 36 36
42" deep 42 42 42 42 42 42
48" deep 48 48 48 48 48 48
54" deep 54 54 54 54 54 54
Diffuser–depth, inches
With housed fan 16 16 16 24 24 24
With inline fan 18 18 22 26 26 28
Attenuator–depth, inches
Short 40 40 40 40 40 40
Medium 52 52 52 52 52 52
Long 64 64 64 64 64 64
Supply or return plenum–depth, inches
Top, bottom or end opening 22 24 28 30 30 32
* Based on typical industry sizes. Vision air handling units are available in 2 inch increments of height and width to fit the exact space requirements.
Front load filter sections include 24" upstream plenum section with tread plate for heavy duty floor liner.

 Physical Data - 045 through 090

Data Unit Size
045 055 065 080 085 090
Airflow range, cfm 9600-25,500 11,400-30,200 20,000-54,000 21,500-57,500 23,100-61,600 24,600-65,600
cfm @ 500 ft/min through large face area coil 19,300 24,500 33,300 35,900 38,450 41,000
Height × width, inches 68 × 116 80 × 120 92 × 136 98 × 136 104 × 136 110 × 136
Cooling coil face area, sq ft
Extended/staggered large 50.4 N/A 76.9 82.0 87.1 92.2
Large 42.6 50.4 66.6 71.8 76.9 82.0
Extended/staggered medium 34.9 46.5 61.5 61.5 66.6 71.8
Medium 31.0 38.8 51.2 51.2 56.4 61.5
Small 27.1 34.9 46.1 46.1 51.2 56.4
Fan section–depth, inches
Largest housed fan & motor avail. w/ top hor. dischg. 58 60 92 92 92 92
Largest inline fan and motor available 82 82 96 96 96 96
Largest belt drive plenum fan & motor available 66 66 82 82 82 82
Largest direct drive plenum fan & motor available 86 902 86 N/A N/A N/A
Largest twin fan and motor available 78 78 N/A N/A N/A N/A
Largest 1 × 3 fan array and motor available 52 52 52 52 52 52
Largest 2 × 2 fan array and motor available 52 52 58 62 64 64
Largest 2 × 3 fan array and motor available 52 52 52 52 52 52
Mixing box–depth, inches
Mixing box only 42 48 46 50 54 56
Mixing box with flat filter 50 54 58 60
Mixing box with angular filter 68 72 76 78
Economizer–depth, inches
  106 112 92 100 108 112
Blender–depth, inches
Largest Kees 64 68 76 80 84 84
Largest Blender Products IV 70 70 88 88 92 92
Side load filter sections–depth, inches
Flat 2" and 4" 12 12 12 12 12 12
2" angular 32 32 32 32 32 32
Cartridge (12" deep w/2" pre-filter) 22 22 22 22 22 22
Bag (36" w/2" pre-filter) 44 44 42 42 42 42
Front load filter sections–depth, inches
Cartridge (12" deep w/2" pre-filter) 20 20 16 16 16 16
Bag (36" w/2" pre-filter) 44 44 40 40 40 40
Face and bypass–depth, inches
Internal 12 12 12 12 12 12
External 44 50 50 54 56 58
Coil sections–depth, inches
Heating only (2-row water) 16 16 12 12 12 12
Cooling only (4-row water) 48 48 18 18 18 18
Cooling only (6-row water) 48 48 24 24 24 24
Cooling & reheat (12-row cooling & 1-row heating) 42 42 36 36 36 36
Access sections–depth, inches
16" deep 16 16 16 16 16 16
24" deep 24 24 24 24 24 24
30" deep 30 30 30 30 30 30
36" deep 36 36 36 36 36 36
42" deep 42 42 42 42 42 42
48" deep 48 48 48 48 48 48
54" deep 54 54 54 54 54 54
Diffuser–depth, inches
With housed fan 30 30 30 30 30 30
With inline fan 30 32 38 38 38 38
Attenuator–depth, inches
Short 40 40 40 40 40 40
Medium 52 52 52 52 52 52
Long 64 64 64 64 64 64
Supply or return plenum–depth, inches
Top, bottom or end opening 32 40 42 48 52 54
* Based on typical industry sizes. Vision air handling units are available in 2 inch increments of height and width to fit the exact space requirements.
Front load filter sections include 24" upstream plenum section with tread plate for heavy duty floor liner.

Downloads